![basic power world simulator projects basic power world simulator projects](https://world-nuclear.org/getmedia/6d75fb5d-2abc-4663-bddf-0cea78c2a25b/sites-of-npps-in-china.png)
![basic power world simulator projects basic power world simulator projects](https://image.slidesharecdn.com/886163ba-df5d-4173-9da6-c5c06048cb53-160124164651/95/electricalpowerengineercv-2-638.jpg)
Supplied with a comprehensive user guide which includes equipment descriptions, theory and experiments. The unit includes an emergency switch, a mains supply isolator and protection fuses. Supplied with the equipment is a set of shrouded leads for the user to connect the test circuits together. The lamps show whether the circuit-breakers are open or closed. The circuit-breakers also include hand-operated switches, and lamps. When a circuit fault happens, the relay opens circuit-breakers in the test circuits.
#BASIC POWER WORLD SIMULATOR PROJECTS SOFTWARE#
The user sets the relay from its local control panel or by a cable link to a suitable computer and software (included). Here you will find professionally designed and easy-to-edit Powerpoint templates curated by our awesome team. Create an informative simple presentation using the following simple powerpoint backgrounds and slides. The relay also monitors and measures fault events and disturbances for fault analysis. Simple is sometimes better because it helps your audience stay focused with no distractions. The user connects and sets the protection relay to detect line and earth currents. Provision to vary the length parametersĪ fault application switch and earth fault resistors allow studies of earth fault currents and the operation of relays of varying sensitivity.įor protection tests, current transformers (CTs) in the test circuits connect to the protection relay fitted to the control panel.Operating under variable balanced or unbalanced RLC (resistive, inductive and capacitive) loads.The three-phase transmission line is in six sections represented in ‘per-unit’ values. monitor the voltage, current and power at any point along the line.set up ‘Pi’ or ‘Tee’ methods of loss profiling using different values of capacitance and.change the length of the simulated line.The single-phase transmission line includes a set of inductive impedances connected in series. The effects can be monitored by instruments at the send and receive ends of the transmission lines. The lines may be loaded by the resistive, capacitive and inductive loads included. The upper panel has a single-phase transmission line equivalent circuit, and the lower panel a three-phase transmission line. The console is divided into two control panels, each with detailed mimic diagrams. The configurable simulated transmission lines allow realistic studies of short, medium and long-distance transmission lines under variable load and power factor conditions, as well as with inserted faults. The Transmission Line Simulator investigates single-phase and three-phase transmission lines.